Fired Heater Safety Standards and Burner Management
Forums
Blogs
Library/Resources
Members
Tags
More
Cancel
Create New Post
Comment or Question? Become a member of this Emerson Exchange 365 group. Click here to join.
Jim Cahill
2 Apr 2013
Nikki Bishop
reformer unit
IEC 61511
Dave Sheppard
Refining
hydrocracker
fired heater
safety instrumented function
Safety
NFPA 86
burner management
safety instrumented system
API RP 556
refinery
Options
Subscribe by email
RSS
More
Cancel
Related
Recommended
Share
Fired Heater Safety Standards and Burner Management
In an earlier post, Safety System Considerations for Process Fired Heaters, I highlighted an American Fuel & Petrochemical Manufacturers (AFPM) paper by Emerson’s Nikki Bishop and Dave Sheppard. In this post, I’ll share the safety system design, selection and estimated savings in startup time reductions from the paper. The authors note that safety instrumented systems [...]
Sign in to reply
Parents
Jim Cahill
over 4 years ago
Hi Steve, Here's some feedback I received. "Assuming the fired heater is greater than 12,500,000 Btu/hr, I would recommend looking at NFPA 87, specifically chapter 8 which would deal with the safety equipment and its application to the fluid heater heating system. That chapter lays out what is required and what is recommended for the BMS. I can go through and list the interlocks it calls out, but without knowing what the system looks like, I’d be listing items that may or may not be applicable. As to what would be the most important, that’s a bit like asking what your favorite brick in a wall would be. They all are equally important to the burner safety system and, if called out by NFPA 87, required by the best practices surrounding the heater."
Cancel
Vote Up
0
Vote Down
Sign in to reply
More
Cancel
Comment
Jim Cahill
over 4 years ago
Hi Steve, Here's some feedback I received. "Assuming the fired heater is greater than 12,500,000 Btu/hr, I would recommend looking at NFPA 87, specifically chapter 8 which would deal with the safety equipment and its application to the fluid heater heating system. That chapter lays out what is required and what is recommended for the BMS. I can go through and list the interlocks it calls out, but without knowing what the system looks like, I’d be listing items that may or may not be applicable. As to what would be the most important, that’s a bit like asking what your favorite brick in a wall would be. They all are equally important to the burner safety system and, if called out by NFPA 87, required by the best practices surrounding the heater."