<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://emersonexchange365.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:slash="http://purl.org/rss/1.0/modules/slash/" xmlns:wfw="http://wellformedweb.org/CommentAPI/"><channel><title /><link>https://emersonexchange365.com/</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 13</generator><item><title>Blog Post: Edge Computing Enables Industrial AI Without Compromising OT Integrity</title><link>https://emersonexchange365.com/iiot-digital-transformation/b/weblog/posts/edge-computing-enables-industrial-ai-without-compromising-ot-integrity</link><pubDate>Tue, 23 Jun 2026 12:34:00 GMT</pubDate><guid isPermaLink="false">cd40bb2b-3d49-4868-939d-417119b40291:2ce402ad-b9bc-496a-8d05-060f26e5d8c8</guid><dc:creator>Jim Cahill</dc:creator><description>Why this matters now Many industrial organizations are at an operational inflection point. A global, highly competitive marketplace demands greater efficiency and optimization, yet many of the most powerful analytical and AI-driven tools live in the cloud. Operational technology (OT) environments have historically resisted cloud connectivity to ensure security, determinism, and protection of intellectual property. […] The post Edge Computing Enables Industrial AI Without Compromising OT Integrity appeared first on the Emerson Automation Experts blog.</description><category domain="https://emersonexchange365.com/tags/digital%2btransformation">digital transformation</category><category domain="https://emersonexchange365.com/tags/cybersecurity">cybersecurity</category><category domain="https://emersonexchange365.com/tags/Control%2b_2600_amp_3B00_%2bSafety%2bSystems">Control &amp;amp; Safety Systems</category><category domain="https://emersonexchange365.com/tags/Edge%2bComputing">Edge Computing</category><category domain="https://emersonexchange365.com/tags/Enterprise%2boperations%2bplatform">Enterprise operations platform</category><category domain="https://emersonexchange365.com/tags/EOP">EOP</category><category domain="https://emersonexchange365.com/tags/LLM">LLM</category><category domain="https://emersonexchange365.com/tags/OT_2F00_IT%2bConvergence">OT/IT Convergence</category><category domain="https://emersonexchange365.com/tags/Industrial%2bAI">Industrial AI</category><category domain="https://emersonexchange365.com/tags/Software">Software</category><category domain="https://emersonexchange365.com/tags/DeltaV">DeltaV</category></item><item><title>Forum Post: RE: Offline DV Explorer (Tool)</title><link>https://emersonexchange365.com/community-hubs/deltav-community-connect/f/deltav-discussions-questions/2855/offline-dv-explorer-tool/25364</link><pubDate>Mon, 22 Jun 2026 19:41:00 GMT</pubDate><guid isPermaLink="false">cd40bb2b-3d49-4868-939d-417119b40291:2c394422-0e2d-45c2-adda-1cfd43426869</guid><dc:creator>Abhi</dc:creator><description>Hi, Could you please let me know how I can get access to the FHX Viewer tool?</description></item><item><title>Blog Post: Smarter Control Valves, Better Operating Decisions: A Conversation with Clint Schneider</title><link>https://emersonexchange365.com/community-hubs/valves-actuators-regulators/b/vcp-weblog/posts/smarter-control-valves-better-operating-decisions-a-conversation-with-clint-schneider</link><pubDate>Mon, 22 Jun 2026 16:00:00 GMT</pubDate><guid isPermaLink="false">cd40bb2b-3d49-4868-939d-417119b40291:8b3e519c-ba95-4c17-9a59-8f8d3420b948</guid><dc:creator>Jim Cahill</dc:creator><description>Control valves sit at the point where process decisions become physical actions. Better data from the valve, delivered to the right person in the right place, shortens the path from detection to response. The post Smarter Control Valves, Better Operating Decisions: A Conversation with Clint Schneider appeared first on the Emerson Automation Experts blog.</description><category domain="https://emersonexchange365.com/tags/Clint%2bSchneider">Clint Schneider</category><category domain="https://emersonexchange365.com/tags/Valves_2C00_%2bActuators%2b_2600_amp_3B00_%2bRegulators">Valves, Actuators &amp;amp; Regulators</category><category domain="https://emersonexchange365.com/tags/podcast">podcast</category><category domain="https://emersonexchange365.com/tags/ValveLink">ValveLink</category><category domain="https://emersonexchange365.com/tags/ENVIRO_2D00_SEAL">ENVIRO-SEAL</category><category domain="https://emersonexchange365.com/tags/Downstream%2bHydrocarbons">Downstream Hydrocarbons</category><category domain="https://emersonexchange365.com/tags/Fisher">Fisher</category><category domain="https://emersonexchange365.com/tags/FIELDVUE%2bDVC7K">FIELDVUE DVC7K</category></item><item><title>Blog Post: Smarter Control Valves, Better Operating Decisions: A Conversation with Clint Schneider</title><link>https://emersonexchange365.com/industries/refining/b/weblog/posts/smarter-control-valves-better-operating-decisions-a-conversation-with-clint-schneider</link><pubDate>Mon, 22 Jun 2026 16:00:00 GMT</pubDate><guid isPermaLink="false">cd40bb2b-3d49-4868-939d-417119b40291:e18e1d12-1f24-4d69-8daf-14fe350fe3d0</guid><dc:creator>Jim Cahill</dc:creator><description>Control valves sit at the point where process decisions become physical actions. Better data from the valve, delivered to the right person in the right place, shortens the path from detection to response. The post Smarter Control Valves, Better Operating Decisions: A Conversation with Clint Schneider appeared first on the Emerson Automation Experts blog.</description><category domain="https://emersonexchange365.com/tags/Clint%2bSchneider">Clint Schneider</category><category domain="https://emersonexchange365.com/tags/Valves_2C00_%2bActuators%2b_2600_amp_3B00_%2bRegulators">Valves, Actuators &amp;amp; Regulators</category><category domain="https://emersonexchange365.com/tags/podcast">podcast</category><category domain="https://emersonexchange365.com/tags/ValveLink">ValveLink</category><category domain="https://emersonexchange365.com/tags/ENVIRO_2D00_SEAL">ENVIRO-SEAL</category><category domain="https://emersonexchange365.com/tags/Downstream%2bHydrocarbons">Downstream Hydrocarbons</category><category domain="https://emersonexchange365.com/tags/Fisher">Fisher</category><category domain="https://emersonexchange365.com/tags/FIELDVUE%2bDVC7K">FIELDVUE DVC7K</category></item><item><title>Blog Post: Smart Solutions for Emerging Pipeline Priorities</title><link>https://emersonexchange365.com/community-hubs/valves-actuators-regulators/b/vcp-weblog/posts/smart-solutions-for-emerging-pipeline-priorities</link><pubDate>Mon, 22 Jun 2026 08:00:00 GMT</pubDate><guid isPermaLink="false">cd40bb2b-3d49-4868-939d-417119b40291:5b2c1fe9-2356-4eb5-9cd6-0a2a7cc10f96</guid><dc:creator>Jim Cahill</dc:creator><description>Evang&amp;#233;line Cousot&amp;#39;s World Pipelines article, “Pipelines under pressure,” explains how smart technology and integrated biomethane injection stations support sustainability improvement initiatives for distribution system operators (DSOs). The post Smart Solutions for Emerging Pipeline Priorities appeared first on the Emerson Automation Experts blog.</description><category domain="https://emersonexchange365.com/tags/Valves_2C00_%2bActuators%2b_2600_amp_3B00_%2bRegulators">Valves, Actuators &amp;amp; Regulators</category><category domain="https://emersonexchange365.com/tags/Sustainable%2bEnergy">Sustainable Energy</category></item><item><title>Forum Post: RE: Operator Workstation Runtime Shows Empty Data Paths After Rebuild – No Server Access</title><link>https://emersonexchange365.com/community-hubs/deltav-community-connect/f/deltav-discussions-questions/11444/operator-workstation-runtime-shows-empty-data-paths-after-rebuild-no-server-access/25363</link><pubDate>Mon, 22 Jun 2026 05:10:00 GMT</pubDate><guid isPermaLink="false">cd40bb2b-3d49-4868-939d-417119b40291:5373f22d-9bea-4d95-a536-df249f816c69</guid><dc:creator>Rishi Prajapati</dc:creator><description>Try the following: 1. Copy the entire YellowPages folder from Pro+ &amp;amp; overwrite it in the Operator Station. 2. Download this Operator Station from DV Explorer. Now this operator station should show all datalinks with proper real time values in DV Operate Run.</description></item><item><title>Blog Post: 다상 유량계(MPFM) 오차 줄이는 법, 에머슨 Roxar 2600의 스마트 자가 진단 기술</title><link>https://emersonexchange365.com/worlds/south_korea/b/emerson-korea-blog/posts/mpfm-roxar-2600</link><pubDate>Sun, 21 Jun 2026 23:00:00 GMT</pubDate><guid isPermaLink="false">cd40bb2b-3d49-4868-939d-417119b40291:a82d2f69-1ab4-4d35-8efc-870fab87b29b</guid><dc:creator>Emerson South Korea Blog</dc:creator><description>다상 유량계(MPFM) 오차 줄이는 법, 에머슨 Roxar 2600의 스마트 자가 진단 기술 Original : Intelligent Diagnostics, Deeper Insight, and Confidence in Every Multiphase Measurement By Kelda Dinsdale 플랜트 운영자의 측정 계측 접근법과 자산 최적화 공정에서 다상 유량계(MPFM)의 역할이 갈수록 중요해지고 있습니다. 이에 따라 다상 유량계가 최적의 성능을 발휘하고 있는지 확인하고 신뢰성을 확보하는 일 역시 핵심 과제로 떠올랐습니다. 그러나 유량 측정 성능을 검증하고 제대로 관리하기 위해서는 높은 수준의 전문 지식이 필요합니다. 바로 이 분야에서 글로벌 자동화 전문 기업 에머슨(Emerson)의 혁신적인 다상 유량계, Roxar .......</description><category domain="https://emersonexchange365.com/tags/_90C7D9B354D694C1E8B858C1_">자동화솔루션</category></item><item><title>Forum Post: RE: OPC HDA Server tag unknown to DVCH</title><link>https://emersonexchange365.com/community-hubs/deltav-community-connect/f/deltav-discussions-questions/11466/opc-hda-server-tag-unknown-to-dvch/25362</link><pubDate>Fri, 19 Jun 2026 18:32:00 GMT</pubDate><guid isPermaLink="false">cd40bb2b-3d49-4868-939d-417119b40291:a44100f9-0ecb-49ef-84ad-6c197ba34b8b</guid><dc:creator>Kent</dc:creator><description>Thanks for the quick response. The problem is that the error often, but not always, is for a tag from an AI block that feeds a PID block. The only time I historize a value from the AI block is if I&amp;#39;m filtering the PID PV and I also want to be able to see unfiltered as well as filtered data. There are also quite a few that are calling for OUT and SP from a DC! block when I only historize PV. Very puzzling.</description></item><item><title>Forum Post: RE: OPC HDA Server tag unknown to DVCH</title><link>https://emersonexchange365.com/community-hubs/deltav-community-connect/f/deltav-discussions-questions/11466/opc-hda-server-tag-unknown-to-dvch/25361</link><pubDate>Fri, 19 Jun 2026 18:15:00 GMT</pubDate><guid isPermaLink="false">cd40bb2b-3d49-4868-939d-417119b40291:3df81144-ea9f-455f-9d64-40722eb5f820</guid><dc:creator>Andre Dicaire</dc:creator><description>My first thought is the history tag is different than what you think. The history tag can include or omit the .CV field. Or the parameter has been abstracted in the module to a module level internal reference, and FIC-101/AI1/PV is historized as FIC-101/PV (with or without CV). Check the Module&amp;#39;s History Collection to confirm the tag is configured exactly as you are trying to read it. If configured, check it hasn&amp;#39;t been disabled. You can also check the PHIST.SCR file located in the DVDATA/Download folder of the historian. This the downloaded runtime configuration of the historian, so if it&amp;#39;s there, then you know the configuration database is in line. Hopefully, you find a discrepancy that explains what you are seeing. If the PHIST file has the tag as you are searching for it, we have a mystery and a call to the GSC is likely warranted. When using PHV to view history, DeltaV does not have a focused list of configured available history tag. You browse the entire name space, in case you want to trend a value in real time that is not historized. But if you don&amp;#39;t know the historized tag path (syntax), you have to try variations or check the History collection of the tag. Wouldn&amp;#39;t it be nice if you could enter or browse a tag and see select from the focused list of historized tags of that module? Hmm. Then you wouldn&amp;#39;t have to guess the tag name or navigate the module parameter tree to get to the tag you think you want. good luck.</description></item><item><title>Blog Post: Successful IIoT Starts with the End Goal, Not the Technology</title><link>https://emersonexchange365.com/iiot-digital-transformation/b/weblog/posts/successful-iiot-starts-with-the-end-goal-not-the-technology</link><pubDate>Fri, 19 Jun 2026 16:00:00 GMT</pubDate><guid isPermaLink="false">cd40bb2b-3d49-4868-939d-417119b40291:429e4e79-61b7-48f0-b4b2-f5b8e7faff9c</guid><dc:creator>Jim Cahill</dc:creator><description>Why this matters now In today’s increasingly connected world of industrial manufacturing, IIoT options abound. Yet while having options is a good thing, too many options can make it difficult to identify the right technologies to meet an organization’s unique circumstances. As Manish Sharma explores in a recent article in Control, organizations must first align […] The post Successful IIoT Starts with the End Goal, Not the Technology appeared first on the Emerson Automation Experts blog.</description><category domain="https://emersonexchange365.com/tags/digital%2btransformation">digital transformation</category><category domain="https://emersonexchange365.com/tags/Industrial%2bPCs">Industrial PCs</category><category domain="https://emersonexchange365.com/tags/GHG">GHG</category><category domain="https://emersonexchange365.com/tags/Control%2b_2600_amp_3B00_%2bSafety%2bSystems">Control &amp;amp; Safety Systems</category><category domain="https://emersonexchange365.com/tags/Edge%2bComputing">Edge Computing</category><category domain="https://emersonexchange365.com/tags/PACEdge">PACEdge</category><category domain="https://emersonexchange365.com/tags/EOP">EOP</category><category domain="https://emersonexchange365.com/tags/IIoT">IIoT</category><category domain="https://emersonexchange365.com/tags/CPL410">CPL410</category><category domain="https://emersonexchange365.com/tags/Data%2bManagement">Data Management</category><category domain="https://emersonexchange365.com/tags/PACsystems">PACsystems</category><category domain="https://emersonexchange365.com/tags/connectivity">connectivity</category><category domain="https://emersonexchange365.com/tags/Oil%2b_2600_amp_3B00_%2bGas">Oil &amp;amp; Gas</category><category domain="https://emersonexchange365.com/tags/IPC">IPC</category></item><item><title>Forum Post: OPC HDA Server tag unknown to DVCH</title><link>https://emersonexchange365.com/community-hubs/deltav-community-connect/f/deltav-discussions-questions/11466/opc-hda-server-tag-unknown-to-dvch</link><pubDate>Fri, 19 Jun 2026 15:53:00 GMT</pubDate><guid isPermaLink="false">cd40bb2b-3d49-4868-939d-417119b40291:1bba2e0f-9c4a-4a4a-ac7a-0aebd1622848</guid><dc:creator>Kent</dc:creator><description>I&amp;#39;m getting a very strange error message. It says that a given tag on the DeltaV OPC HDA server is unknown to the DVCH. The tag exists but is not in the historian and never has been that I know of. The HDA server connects to a OPC HDA interface to send data to PI. The tags in question are not in PI either. I looked at the HDA server with the HDA Tool that comes with the PI interface and I don&amp;#39;t see any of the tags in question on the HDA server. Any suggestions on how to troubleshoot this? I&amp;#39;m puzzled.</description></item><item><title>Blog Post: For Data Center Cooling, the Right Instrumentation Increases Reliability, Efficiency, and Uptime</title><link>https://emersonexchange365.com/industries/otherindustries/industrial-energy/b/weblog/posts/for-data-center-cooling-the-right-instrumentation-increases-reliability-efficiency-and-uptime</link><pubDate>Fri, 19 Jun 2026 13:00:00 GMT</pubDate><guid isPermaLink="false">cd40bb2b-3d49-4868-939d-417119b40291:921eb275-130e-42c2-8df2-1ad9bbb23c4a</guid><dc:creator>Jim Cahill</dc:creator><description>The need for data center energy management is nothing new, as it extends back to the beginnings of the internet and has kept growing. Lately, the growth curve has taken a sharp turn up with new AI platforms creating the need for increasing equipment density. The result? Heat, and lots of it. The scale of […] The post For Data Center Cooling, the Right Instrumentation Increases Reliability, Efficiency, and Uptime appeared first on the Emerson Automation Experts blog.</description><category domain="https://emersonexchange365.com/tags/Industrial%2bEnergy%2b_2600_amp_3B00_%2bOnsite%2bUtilities">Industrial Energy &amp;amp; Onsite Utilities</category><category domain="https://emersonexchange365.com/tags/Measurement%2bInstrumentation">Measurement Instrumentation</category><category domain="https://emersonexchange365.com/tags/Flexim%2bflow%2bmeter">Flexim flow meter</category><category domain="https://emersonexchange365.com/tags/Travis%2bTeeter">Travis Teeter</category><category domain="https://emersonexchange365.com/tags/thermal%2benergy%2bflow%2bmeter">thermal energy flow meter</category><category domain="https://emersonexchange365.com/tags/clamp%2bon%2bflow%2bmeter">clamp on flow meter</category><category domain="https://emersonexchange365.com/tags/ultrasonic%2bflow%2bmeter">ultrasonic flow meter</category><category domain="https://emersonexchange365.com/tags/AI%2bdata%2bcenter%2bcooling">AI data center cooling</category><category domain="https://emersonexchange365.com/tags/data%2bcenter%2bcooling">data center cooling</category><category domain="https://emersonexchange365.com/tags/Fluxus%2bflow%2bmeter">Fluxus flow meter</category><category domain="https://emersonexchange365.com/tags/Tri_2D00_T%2bEnergy%2bSolutions">Tri-T Energy Solutions</category><category domain="https://emersonexchange365.com/tags/Non_2D00_intrusive%2binstrumentation">Non-intrusive instrumentation</category></item><item><title>Forum Post: New Delta V monitors</title><link>https://emersonexchange365.com/community-hubs/deltav-community-connect/f/deltav-discussions-questions/11465/new-delta-v-monitors</link><pubDate>Thu, 18 Jun 2026 20:16:00 GMT</pubDate><guid isPermaLink="false">cd40bb2b-3d49-4868-939d-417119b40291:7db5f738-6f1c-4f4d-954c-5dfb6e0758dc</guid><dc:creator>Steven Harris</dc:creator><description>Looking to move from the Dell P2213 WXSGA+ to the larger 24&amp;quot; WUXGA screens. Has anyone experienced any problems doing that?</description></item><item><title>Blog Post: Engineering Pressure and Temperature Transducers for the Harshest Places on Earth and Beyond</title><link>https://emersonexchange365.com/community-hubs/measurement-instrumentation/b/pressure-weblog/posts/engineering-pressure-and-temperature-transducers-for-the-harshest-places-on-earth-and-beyond</link><pubDate>Thu, 18 Jun 2026 13:00:00 GMT</pubDate><guid isPermaLink="false">cd40bb2b-3d49-4868-939d-417119b40291:f059d0e9-d8b0-4179-9394-f64858e3f236</guid><dc:creator>Jim Cahill</dc:creator><description>Pressure and temperature measurement underpins safety and productivity across upstream oil and gas, subsea systems, and aerospace. When a sensor sits next to a perforating charge thousands of feet downhole or rides aboard a satellite, replacing it is either prohibitively expensive or impossible. The post Engineering Pressure and Temperature Transducers for the Harshest Places on Earth and Beyond appeared first on the Emerson Automation Experts blog.</description><category domain="https://emersonexchange365.com/tags/Paine%2bElectronics">Paine Electronics</category><category domain="https://emersonexchange365.com/tags/Pressure">Pressure</category><category domain="https://emersonexchange365.com/tags/Nick%2bThelin">Nick Thelin</category><category domain="https://emersonexchange365.com/tags/Rosemount">Rosemount</category><category domain="https://emersonexchange365.com/tags/Jason%2bThompson">Jason Thompson</category><category domain="https://emersonexchange365.com/tags/Temperature">Temperature</category><category domain="https://emersonexchange365.com/tags/Tom%2bHansen">Tom Hansen</category></item><item><title>Blog Post: Engineering Pressure and Temperature Transducers for the Harshest Places on Earth and Beyond</title><link>https://emersonexchange365.com/community-hubs/measurement-instrumentation/b/temperature-weblog/posts/engineering-pressure-and-temperature-transducers-for-the-harshest-places-on-earth-and-beyond</link><pubDate>Thu, 18 Jun 2026 13:00:00 GMT</pubDate><guid isPermaLink="false">cd40bb2b-3d49-4868-939d-417119b40291:3caac47d-9bcd-4d31-a597-01dd1d87d460</guid><dc:creator>Jim Cahill</dc:creator><description>Pressure and temperature measurement underpins safety and productivity across upstream oil and gas, subsea systems, and aerospace. When a sensor sits next to a perforating charge thousands of feet downhole or rides aboard a satellite, replacing it is either prohibitively expensive or impossible. The post Engineering Pressure and Temperature Transducers for the Harshest Places on Earth and Beyond appeared first on the Emerson Automation Experts blog.</description><category domain="https://emersonexchange365.com/tags/Paine%2bElectronics">Paine Electronics</category><category domain="https://emersonexchange365.com/tags/Pressure">Pressure</category><category domain="https://emersonexchange365.com/tags/Nick%2bThelin">Nick Thelin</category><category domain="https://emersonexchange365.com/tags/Rosemount">Rosemount</category><category domain="https://emersonexchange365.com/tags/Jason%2bThompson">Jason Thompson</category><category domain="https://emersonexchange365.com/tags/Temperature">Temperature</category><category domain="https://emersonexchange365.com/tags/Tom%2bHansen">Tom Hansen</category></item><item><title>Blog Post: 클라우드는 늦다! 엣지 컴퓨팅 기반 '산업용 AI'에 주목하는 이유</title><link>https://emersonexchange365.com/worlds/south_korea/b/emerson-korea-blog/posts/ai-1516763310</link><pubDate>Wed, 17 Jun 2026 23:00:00 GMT</pubDate><guid isPermaLink="false">cd40bb2b-3d49-4868-939d-417119b40291:965006ba-b3c2-4fa9-b1c9-7664958cc275</guid><dc:creator>Emerson South Korea Blog</dc:creator><description>클라우드는 늦다! 엣지 컴퓨팅 기반 &amp;#39;산업용 AI&amp;#39;에 주목하는 이유 Original : Edge-Based AI Reshapes Industrial Operations By Todd Walden, Amy Schantz 수년 동안 제조업의 디지털 트랜스포메이션(DX, Digital Transformation)은 정체된 것 처럼 보였습니다. 운영기술(OT)티팀은 새로운 센서 장비와 소프트웨어를 도입해 방대한 양의 데이터를 수집해 왔지만, 정작 이 데이터들을 현장에 즉각 적용할 수 있는 &amp;#39;실행 가능한 정보&amp;#39;로 변환하는 데는 어려움을 겪었습니다. 가장 큰 원인 중 하나는 디지털 혁신을 위해 도입한 기술들이 역설적으로 조직 내에 또 다른 데이터 사일로(Data Silo, 데이터 고립)를 만들어냈기 때.......</description><category domain="https://emersonexchange365.com/tags/_14B5C0C938D1_%2b_B8D29CB7A4C2ECD354BA74C758C1_">디지털 트랜스포메이션</category></item><item><title>Forum Post: How do I know if my M-Series 8-wide carrier was manufactured after 2002?</title><link>https://emersonexchange365.com/community-hubs/deltav-community-connect/f/deltav-discussions-questions/11464/how-do-i-know-if-my-m-series-8-wide-carrier-was-manufactured-after-2002</link><pubDate>Tue, 16 Jun 2026 13:24:00 GMT</pubDate><guid isPermaLink="false">cd40bb2b-3d49-4868-939d-417119b40291:28c50689-1763-494b-9e52-40768fdd0689</guid><dc:creator>Luis Alberto Navas Guzman</dc:creator><description>We want to replace some MD+ controllers with PK controllers. The PK controller only supports 8-wide carriers manufactured after 2002. Seeing my serial number T0832..... seems that i was built on year 2008 week 32. Am i Right? Thank you!</description></item><item><title>Forum Post: RE: 2700 Tx to 5700 Tx upgrade/change out error message " device description"</title><link>https://emersonexchange365.com/community-hubs/measurement-instrumentation/f/flow-discussions-questions/11463/2700-tx-to-5700-tx-upgrade-change-out-error-message-device-description/25360</link><pubDate>Tue, 16 Jun 2026 13:14:00 GMT</pubDate><guid isPermaLink="false">cd40bb2b-3d49-4868-939d-417119b40291:31b9716a-305d-4eaa-89c8-1dd93376a662</guid><dc:creator>Jared Drennen</dc:creator><description>It sounds like the new transmitter is not properly recognizing the sensor type (via the 700 core processor on the sensor). The sensor should be recognized as soon as all of the Flow Calibration Factors are programmed into the new electronics (as stamped on the sensor tag, or published on the associated calibration certificate). If you are still receiving error alerts after these parameters are programmed, please reach out to Flow.Support@Emerson.com with the actual error codes, or call 800-522-6277 for phone support while you are connected to the device (if possible).</description></item><item><title>Blog Post: How Industrial AI and Data Orchestration Are Redefining Operational Excellence</title><link>https://emersonexchange365.com/iiot-digital-transformation/b/weblog/posts/how-industrial-ai-and-data-orchestration-are-redefining-operational-excellence</link><pubDate>Tue, 16 Jun 2026 12:31:00 GMT</pubDate><guid isPermaLink="false">cd40bb2b-3d49-4868-939d-417119b40291:37adf512-db66-4a50-b605-be6aa1ecb0f0</guid><dc:creator>Jim Cahill</dc:creator><description>Why this matters now In modern process manufacturing, the definition of operational excellence has fundamentally changed. Organizations are no longer responsible for optimizing a single facility; instead, many operate expansive enterprises spanning multiple sites and regions, all of which must work in concert to remain competitive. As a result, teams are expected to improve efficiency, […] The post How Industrial AI and Data Orchestration Are Redefining Operational Excellence appeared first on the Emerson Automation Experts blog.</description><category domain="https://emersonexchange365.com/tags/digital%2btransformation">digital transformation</category><category domain="https://emersonexchange365.com/tags/Data%2bOrchestration">Data Orchestration</category><category domain="https://emersonexchange365.com/tags/Control%2b_2600_amp_3B00_%2bSafety%2bSystems">Control &amp;amp; Safety Systems</category><category domain="https://emersonexchange365.com/tags/Enterprise%2boperations%2bplatform">Enterprise operations platform</category><category domain="https://emersonexchange365.com/tags/EOP">EOP</category><category domain="https://emersonexchange365.com/tags/automation">automation</category><category domain="https://emersonexchange365.com/tags/AI">AI</category><category domain="https://emersonexchange365.com/tags/Industrial%2bAI">Industrial AI</category><category domain="https://emersonexchange365.com/tags/Operational%2bExcellence">Operational Excellence</category><category domain="https://emersonexchange365.com/tags/Software">Software</category><category domain="https://emersonexchange365.com/tags/OT">OT</category></item><item><title>Forum Post: RE: Operator Workstation Runtime Shows Empty Data Paths After Rebuild – No Server Access</title><link>https://emersonexchange365.com/community-hubs/deltav-community-connect/f/deltav-discussions-questions/11444/operator-workstation-runtime-shows-empty-data-paths-after-rebuild-no-server-access/25359</link><pubDate>Mon, 15 Jun 2026 16:23:00 GMT</pubDate><guid isPermaLink="false">cd40bb2b-3d49-4868-939d-417119b40291:95dea891-7809-41d4-86f8-71b689bdf4e5</guid><dc:creator>Ralf Baginski</dc:creator><description>You shouldn‘t copy the whole graphics folder from other workstations, in subfolder (can‘t remember the name) is a file which refer to the local network name. Maybe you can see this in configure mode on any picture file, do not open it, only right click and select properties. You should see the reference of this file refers to the workstation you copied the folder from. It‘s not easy to resolve this, as you have no backup of this file. May another workstation configuration helps or reinstall DeltaV. You should only copy the pic, Charts folder and the scheduler, layout files. Regards Ralf</description></item></channel></rss>